[ <--- prev -- ] [ HOME ] [ -- next ---> ]
sets time cutoffs and/or quenching factors when scoring using the
USRBIN or the EVENTBIN options.
See also TIME-CUT
WHAT(1) > 0.0 : time cutoff for scoring (seconds) < 0.0 : resets any previously requested time cutoff to default (infinity) = 0.0 : ignored
WHAT(2) > 0.0 : first Birks law coefficient in g/(MeV cm2) = 0.0 : ignored < 0.0 : resets both Birks law coefficients to default = 0.0 WHAT(3) > 0.0 : second Birks law coefficient in g2/(MeV2 cm4) Default = 0.0
WHAT(4) = lower index bound of binnings in which the requested scoring time cutoff and/or Birks law coefficients must be applied ("From binning WHAT(4)...") Default = 1.0
WHAT(5) = upper index bound of binnings in which the requested scoring time cutoff and/or Birks law coefficients must be applied ("...To binning WHAT(5)..." Default = WHAT(4)
WHAT(6) = step length in assigning indices ("...in steps of WHAT(6)"). Default = 1.0
SDUM : not used Default (option TCQUENCH not given): no time cutoff for scoring and no quenching of dose binning
Notes:
dE' = dE/(1 + BS + CS**2)
with B = first Birks parameter and C = Chou or second Birks parameter [Bir64].
Example:
*...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8 TCQUENCH 20.0 7.35E-3 1.45E-5 4.0 10.0 3.0 * Set a 20 sec time scoring cutoff for binnings 4, 7 and 10, and apply to * them the NE213 scintillator Birks parameters published by Craun and * Smith, Nucl. Instr. Meth. 80, 239 (1970)